The ADS Enigma® is a state-of-the-art digital correlation logging system for determining the
location of leaks in buried water pipes. Enigma combines noise logging and noise correlation
into one operation to provide improved operational eciency.
QUICK REFERENCE GUIDE
Programming of the ADS Enigma
®
ADS Enigma Pod -
Installation on Water Meter.
From the PC, run the Enigma
software by clicking on the
desktop icon or programs menu.
1
These two buttons are the
logger Programming and
Readback buttons.
(The Enigma case lid must be
closed when programming or
reading back loggers via the
software.)
2
Ensure the USB communications
cable is connected. Click on the
Program button which will
produce the following progress
box.
3
The Programming wizard will
appear and is usually set for the
default use of Timed Logging
(overnight) as shown.
The settings shown are those
recommended by Primayer and
used by many users.
4
Click on Program.
5
The screen should indicate
that it has found all the
loggers in the case and give
any relevant warnings.
Continued on reverse side.